1. Switch on the wall and the electronics.
Do this by switching on the mean switch and the lightwall (on the back). So switch on the multimeters. See photos 1 and 2
2. Adjust the upper and lower beam to the right cell height. Do this with 2 people. See photo 3
3. Check if there is no power on the cables coming from the power beam. Use the multimeters for this.
4. Connect the cells with the cables.
5. Check the cells with the protocol “Q3 quality finished cell”.
6. Use the right voltages for the different products. 24V for ddLC and 46V for scatter.
7. When doing the capacity measurement, turn the black switching knob from “power” to “R/C”. When done turn it back to “power”
8. When you have ddLC cells use the lightwall and the rotatable polar.
9. If you have scatter cells remove the lightwall and use the spotlight. For swtiching on/of this spotlight you can use the remote control. See photo 4.
Knjdpfx Aev Ep U Aebkoc
10. When you are done, please use the mainswitch to power down, and switch of the used lights.
دغه اعلان په اتوماتيک ډول ژباړل شوی. د ژباړې تېروتنې کېدای شي موجود وي.
Do this by switching on the mean switch and the lightwall (on the back). So switch on the multimeters. See photos 1 and 2
2. Adjust the upper and lower beam to the right cell height. Do this with 2 people. See photo 3
3. Check if there is no power on the cables coming from the power beam. Use the multimeters for this.
4. Connect the cells with the cables.
5. Check the cells with the protocol “Q3 quality finished cell”.
6. Use the right voltages for the different products. 24V for ddLC and 46V for scatter.
7. When doing the capacity measurement, turn the black switching knob from “power” to “R/C”. When done turn it back to “power”
8. When you have ddLC cells use the lightwall and the rotatable polar.
9. If you have scatter cells remove the lightwall and use the spotlight. For swtiching on/of this spotlight you can use the remote control. See photo 4.
Knjdpfx Aev Ep U Aebkoc
10. When you are done, please use the mainswitch to power down, and switch of the used lights.