Climate test chamber 1540 litersWeiss
WK1-1500/40 Temp. -40°C bis +180°C
Climate test chamber 1540 liters
Weiss
WK1-1500/40 Temp. -40°C bis +180°C
حالت
استعمال شوی
ځای
Borken 

انځورونه ښیي
نقشه ښکاره کړئ
د ماشین په اړه معلومات
بیه او موقعیت
- ځای:
- Einsteinstraße 8a, 46325 Borken, DE
تماس وکړئ
د وړاندیز توضیحات
- اعلان ID:
- A19696111
- د حوالې شمېره:
- 24738
- تازه کول:
- وروستي ځل په ۱۰.۰۵.۱۴۰۴
تشريح
Weiss
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Gsdpfx Abow Hcttekjkc
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
دغه اعلان په اتوماتيک ډول ژباړل شوی. د ژباړې تېروتنې کېدای شي موجود وي.
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Gsdpfx Abow Hcttekjkc
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.